Electrochemical Corrosion Testing
The assessment of the extent of ongoing corrosion damage is a critical step in the assessment of structures. The amount and extent of ongoing corrosion is a critical parameter in the selection of means and methods for repairs. To evaluate corrosion, WDP engineers have a variety of electro- chemical test methods available. The methods utilized by WDP engineers include: 
  • Copper - Copper Sulfate Half Cells (ASTM C 876) 
  • Linear Polarization Device 
  • Concrete Resistivity Equipment 
These techniques allow WDP engineers to make informed judgements about the true nature of ongoing corrosion problems in structures. These judgements can be then translated into long-term strategies for structural repairs. 
 
Structures susceptible to ongoing corrosion damage include:
  • Concrete bridge piers 
  • Concrete sea walls 
  • Parking garage slabs 
  • Water storage tanks 
  • Unprotected reinforced concrete masonry walls 